Products

HL50R-C Analogue High Frequency X-ray Machine
Category:
Stationary X-ray System
{{variant.name}}:
{{opt.name}}
{{opt.value ? '' : opt.name}}
{{opt.value ? '' : opt.name}}
Description

Conventional analog radiology

 

 Main Features:

 

 

 

 − Power: 40 KW / 220/230 volts, 20 Amps power supply and high voltage energy (150KV)

drawn from the capacitors.

 

− Switching frequency: 50KHz

 

− The ergonomics of the control panel with excellent supervision of all the parameters

and all the possible settings.

 

− The accuracy and precision of the variation of the radiological parameters KV, mA, mSec

by 03 point technique or KV-mAs by 02 point technique.

RX tube safety and protection, real-time calculator of temperature rise, temperature overload signal.

 

Generator (Bone-Lung)

 

- The Generator with a power of 40 KW can be powered from a reserve of energy stored in capacitors.

50 KHz high-frequency X-ray generator with capacitors, microprocessor controlled.

 

- KV range: from 40 to 150 KV

 

- mA range: 10 to 500 mA

 

- Number of anatomical programs (APR): 1280

The 4-point technique (4-point display: KV, mA, Time, mAs)

 

 

 

 

 

Fixed height table: 

 

Dimensions of the table: 1850x720 mm

 

Height (from the ground): 650mm (+/-10%)

 

Longitudinal displacement: 1000mm

 

Maximum cassette format: up to 36x43cm

 

Dimension of the table: 1850x720 mm

 

Height (from the ground): 650mm (+/-10%)

 

Longitudinal displacement: 1000mm

 

Maximum cassette format: up to 36x43cm

 

 

 

 

X-ray generator DR upgrade reserve interface

 

Fault self-diagnosis and protection

 

Automatic calibration of tube current

 

X-ray tube has the function of filament dormancy

 

AEC function, different ionization chamber as optional

 

Analog-digital double-loop control, simple operation, high intelligence

 

High kV, high current, high power, intense penetration,

able to handle obese patients

 

Applicable to orthopedics, emergency room, operating room, etc.

 

As human head, limbs, chest, spine, and lumbar spine for medical diagnosis.

 

Wall gantry (wall potter bucky)

 

Longitudinal movement: from 500 to 1800 mm

 

Cassette formats up to 36 x 43 cm

 

 

 

 

 

 

Stand (tube holder column)

 

- The multifunctional stand for use in hospitals with a high number of patients.

 

- The use is very simple and fast, the X-ray tube is always online the Potter bucky.

 

 

 

 

 

 

Stand movements

 

- Longitudinal movement: 1000mm minimum

 

- Lateral movement: 200 mm minimum

 

- Vertical movement: from 820 to 1800 mm

 

- X-ray tube rotation: +/- 135°

 

- The Stand uses an electromagnetic brake so that to

control all the braking movements with a respective button

of the movement (vertical, horizontal, rotation of the tube)

is activated so that the movement becomes free.

 

 

 

 

 

 

 

Bright collimator

 

- With an LED or halogen lamp with a 30-second timer, a centering device with LED light is fitted with an integrated tape measure.

 

- It has an equivalent of a 2.0mm Al filter

 

- It is equipped with a permanent electromagnetic brake whose operation is easy to handle without being connected to the current.

 

 

 

 

 

 

 

X-ray tube

 

- 150 KV, 14000UHT (14 kHU) rotating anode tube

 

- Bifocal 1.0mm/2.0mm, 3000rpm, 30/40KW.

 

- Delivered with protective cover.

 

Control desk (console)

 

− The control desk has its support so that the operator can use it in a standing position.

 

- This stand is a standard height for any user’s comfort and height.

 

− The control desk has an exposure control bulb and is connected to the desk by a cable allowing the operator to carry out X-ray launches from any position at the level of the leaded screen.

 

 

 

For a PDF, click here.